Industrial Burn-In Oven: Everything You Need to Know

Different industrial fields utilize burn-in ovens for a host of drying out as well as healing processes. You may have to pick various stoves based on their classifications, capabilities, and configurations for matching various office footprints. The industrial burn-in ovens are developed for dynamic and fixed burn-in of integrated circuits and other digital tools, consisting of laser diodes. Typical burn-in equipment dimensions are from under ten to over 30 cubic feet (0.85 m3), with air or nitrogen arrangements. Running temperatures can review 260 ° C (500 ° F) and make use of both single and multiple temperature setups.

Burn-in ovens can be utilized in various applications such as high-dissipation forward predisposition, high-temperature reverse predisposition, vibrant and fixed burn-in of microprocessors, and other semiconductor tools. The kind and also summary of a commercial burn-in oven depends upon just how it is made use of. Treating ovens create a chemical reaction in between powder and also metal surfaces. Drying out stoves eliminate moisture from basic materials. Various other industrial ovens prepare metals for processing, thaw metals together, and get rid of pollutants.

Picking the right Industrial Burn-In Oven will certainly aid you in fulfilling a host of thermal handling applications. Nevertheless, you ought to beware of satisfying the safety standards as well as preventive specifications.

 

Things to Consider Before Buying a Burn-In Oven for Business Application

As successful and useful as industrial burn-in ovens are, a few factors have to be analyzed when deciding to utilize or buy one.

  • Price

Whether an industrial burn-in oven utilizes electricity or gas, they need the energy to work. Electric burn-in ovens warm up fast and don’t create contamination. They’ve significantly less upfront price but are costly to operate because of their electricity use. Gas industrial ovens are more costly to develop and possess a high upfront cost. Still, they are far less costly to operate because the gasoline cost is lower than the energy cost. Unlike electric, industrial ovens, gas ovens, class A need to possess burst relief as they’re direct or indirect fired. An extra element for gas ovens is availability. Most places have power but no gasoline support. If you consider buying an electric burn-in oven remember, every test center should have enough current/ampere to run the tests. So, your previous energy supply may not be sufficient. Therefore, updating the energy supply may be an additional expense.

 

  • Maintenance

Industrial burn-in oven makers have a listing of recommended daily care tasks that ensure the proper operation. Make sure you get some equipment with the oven to take care of your machine regularly.

 

  • Safety Issues

NFPA has review teams that could be scheduled to assess ovens for upkeep problems frequently. Security Precautions The simplest way to ensure an industrial burn-in gear’s safe operation would be to comply with NFPA 86 criteria. Good training, routine maintenance, and appropriate utilization of an industrial burn-in oven help prevent severe injury and injuries.

Various kinds of substances have individual security requirements, particularly flammable, volatile, or volatile ones. You will find useful guidelines for the handling of every kind. Safety conditions may include:

 

  • Explosion Safe Chamber

Stress release is essential in the event of an explosion in the oven. To get an explosion-proof test environment, the burn-in oven has to have the ability to stop an explosion and stop vapors, gases, dust, or pollutants from tripping.

 

  • Flammable Gas Remove

Flammable vapors and gases need to be purged before the heating element is activated.

 

  • Automated Airflow Safety

The oven won’t operate unless the exhaust fan engine was started and there’s airflow.

 

  • Over Temperature Protection

All these are set higher than the oven’s greatest temperature when there’s too much warmth, a switch shuts the oven down. Contactors are just another fail-safe. They could become fouled. Backups guarantee the oven shuts in over-temperature ailments.

 

  • Fire Protection

All industrial ovens must follow some standard. National fire protection association NFPA, which has a detailed list of regulations for all industrial and commercial equipment. A good industrial burn-in chamber must have a fire protection system enabled.

 

Why DGBell Burn-In Oven are Popular for Industrial Uses?

  • Personalization

We recognize the demand for personalization. We make personalized industrial burn-in ovens based on consumer offered requirements. Suppose you require any requirements chamber dimensions, a particular building, and construction material, and any specific sort of controller. In that case, we can make every possible alteration/ addition at a reasonable rate.

 

  • Special Accessories

There is a variety of optional accessories we supply with our burn-in ovens. Instead of a normal PID controller, we can supply you with a programmable profile PID+PLC controller. We can offer you a touch screen controller, which features selectable programs, time (saturating), in-built information logging, the memory of temperature level information, and date and time. Both inner circulation follower for heating inside the chamber and an exterior fan for cooling down when the examination is completed. You can evaluate ten products, as well as there are 100 steps to evaluate each product. For instance, to examine a flash memory card, when the temperature level increases from 5 ℃ to 10 ℃, this is one step when it takes five minutes. After that, from 10 ℃ to 15 ℃, it takes 5 minutes, this is the second action, and more.

 

  • Support

Our burn-in ovens are provided with a committed functional and service maintenance manual with after-sale support.

 

Conclusion

When deciding to acquire a kind of heating for production, it is extremely important to understand the difference between an industrial burn-in oven and a commercial heater. Individuals often tend to get the two confused. Industrial ovens run at exceptionally heats to warmth treat parts, steels, and manufacturing elements. The usual functions of an industrial burn-in oven are drying, curing, screening, and finishing. The most important commercial oven layout is its airflow, which must be unblocked for full heat saturation.

In most cases, producers use batch or conveyor stoves because of their capability and sturdiness. Though research laboratory stoves meet traditional commercial stoves’ requirements, they are generally created for smaller sized part screening or treatment. Despite the distinction between the three sorts of commercial stoves, it is best to have some expertise of each type, specifically when figuring out which oven fits your production demands. You are highly recommended to consult us before making any decision of buying a burn-in oven.

 

 

 

Read More

Shipping 100 Temperature Environmental Chambers at once!

Wooo!!!! Today our DGBell shipped 100 sets of double-deck high low temperature environmental chamber.

double-deck high low temperature chamber

Then let’s talk about the use of a double-deck high low temperature environment chamber. It is used to test the batteries, battery modules, battery packs, etc, the test temperature range is -40 ℃ – 100 ℃. For example, when testing the cell phone batteries in the cold place will not charge, in the high temperature place will not explode, etc. High low temperature environment chamber is to simulate the performance of the batteries in our actual environment at different temperatures to reduce the battery to our safety brought to harm. A double or triple high low temperature chamber is an independent operation, can test a variety of products at the same time. If you want to know more, you can click here: https://belltestchamber.com/battery-test-chamber/double-deck-high-low-temperature-climatic-simulation-test-machine

Read More

Comprehensive Understanding of Burn-in Chamber

What is a burn-in chamber and where can it be used?

The burn-in chamber can be used to assess and determine the adaptability of electrical,  electronic products or materials for storage, and use under the environmental conditions of high temperature aging on the surface of electrical and electronic products or materials. The burn-in chamber uses forced air circulation to maintain the uniformity of the temperature in the working room.

In order to limit the influence of radiation, the difference between the temperature of each part of the inner wall of the burn-in chamber, the temperature specified in the test is not more than 8%, and the test sample will not be directly radiated by the heating and cooling elements in the burn-in test chamber. burn-in chambers are widely used in power electronics, computers, communications, biopharmaceuticals and other fields.
 

What is the design principle of the burn-in chamber?

Design Principle Description
Practicability, stability and advancement Using advanced and mature technology and equipment to meet current needs, considering the needs of future products, “using, stable, practical” components and materials as much as possible.
Safety and reliability The abnormal aging process adopts dual alarm system (sound and light) to fully protect the safety of the product and the surrounding environment chambers.
Flexibility and scalability Must meet the specific requirements of the proposed design. For future product demand, there must be a certain amount of space to provide. Therefore, the burn-in oven must have good flexibility and scalability. The burn-in oven has the flexibility to support the aging of various models, provide technical upgrades and equipment updates.
Standardization In the structure and principle design of the aging system, according to the relevant standards of the research institute, including the body standard, it has laid a solid foundation for the change of electrical specifications.
Project installability In the design of the aging chamber project, the entire project and equipment adopt a modular structure, which is equivalent to a phased project. The projects of each phase can be seamlessly combined without causing repeated construction and waste.
Economic and investment protection Build cost-effective burn-in environmental test chamber to maximize capital output and investment. It can keep the system running at a lower cost and with fewer personnel. In order to achieve product loading, improve energy and efficiency. As far as possible, keep and expand the actual application of equipment capabilities, and make full use of capital and technical investment.
Manageability Due to the complexity of the burn-in test chamber and the continuous improvement of products required by the burn-in oven, the task of management must become more and more important. Therefore, in the design process, future management must be considered, such as the mobility of a single load, the adjustability of the load, the scalability of the power system, the integration of the control system, and the implementation of humanized design of aging house management.

 

What is the difference between the burn-in chamber and a constant temperature and humidity test chamber?

The function and role of the burn-in equipment can be judged from the name that it is mainly for product aging tests. Generally speaking, the aging test refers to an environmental simulation experiment higher than normal temperature. This kind of simulation experiment refers to a kind of harsh environment with high temperature created artificially, put the product in for a set time, wait until the time is up, take out the product to see if the performance of the product is still intact.

Humidity and low temperature are generally not used in the aging room, but some customers may make industrial products that are high and low-temperature humidity. These experiments are done at the same time, so at this time, a constant temperature and humidity chamber is used. This equipment has more advantages.

It can be done with high and low-temperature humidity, but the disadvantage is that the constant temperature and humidity chamber is not like an aging room. There is no restriction on space. The area of the constant temperature and humidity test chamber is generally relatively small. Only within 50 square meters and the cost will be much larger. This is the difference between the aging room and the constant temperature and humidity test chamber.

 

Does the burn-in room need regular maintenance?

The high and low-temperature aging chamber has a reasonable structure design, complete supporting products and functional parts, which can adapt to long-term, stable and safe, reliable production demand. It is easy to use, operate and maintain, has a long service life, beautiful appearance, and has a good user interface, which makes the user’s operation and monitoring more simple and intuitive.

The aging room has precise temperature control and high precision. Due to the unique air duct system design and electrical control system, it can maintain a high degree of temperature uniformity in the whole room, which is much higher than similar products. Room setting range is temperature, continuously adjustable. The highest temperature of the aging room of DGBell can reach 500 ℃.

Because the burn-in room is at a high temperature for a long time, it needs to be maintained regularly. The high-temperature aging room must strictly abide by the system operation procedures to avoid others violating the operating system, and must be operated and maintained by special personnel. Please pay attention to protection when using, do not hit with force or blunt objects.

The test product placed in the aging room should keep a certain distance from the air inlet and outlet of the air conditioning channel to avoid blocking the airflow. If it is not used for a long time, it will affect the effective service life of the system. Therefore, the system should be turned on and run at least every 10 days. Do not stop the system repeatedly in a short time. The number of starts per hour should be less than 5 times. The stay time at each station is not less than 3 hours.

Open the door in a warm place to prevent damage to the door seal. The operation test of the main power switch (leakage circuit breaker) is carried out regularly every month, to ensure that the switch can be used as a leakage protector under load capacity.

In order to ensure the normal and clean cooling water supply, clean the cooling water filter of the refrigerator every 30 days, and clean the cooling water tower of water supply. If the local air quality is poor and the dust content in the air is high, it should be cleaned and cooled within about 7 days. The water tower tank, the leakage, overload and short circuit protection characteristics of the leakage switch are set by the manufacturer. In the process of use can not be adjusted at will, so as not to affect performance. After opening the leak switch due to a short circuit, check the contacts. If the main contact is severely burned or dented, you need repair pits.

 

Some common questions about burn-in chamber:

  1. When turning on the power indicator light does not light up?
  • Answer: Check whether the power switch is faulty and whether the protective wire is burnt.

 

  1. What’s wrong with the timer?
  • Answer: Check whether the control panel wiring is loose and whether the timer is faulty.

 

  1. Can the pressure of the inner pot increase?
  • Answer: It may be that the manual exhaust valve is not closed, or the drying solenoid valve is faulty / the operating solenoid valve is faulty, or the water distributor is faulty.

 

  1. The pressure of the inner pot increases but the temperature cannot increase?
  • Answer: It may be that there is still pressure in the inner pot after the operation is completed.

 
 
 

Read More

Purchasing Vs Leasing an Environmental Test Chamber

For a huge capital invested company, you may think that leasing an environmental test chamber rather than purchasing one is a reasonable choice. That is not necessarily the situation. Sure, leasing seems sensible for businesses with limited testing wants, but then it takes assiduity for the maintenance of the parts. They should be accountable for preventative care, for example when their needs change, you need to rethink their funding. They often find that they would have profited from the versatility and management of purchasing a test chamber should be your first choice. A well-maintained test chamber can last for ten decades or longer. That is why we advocate working with a respectable maker to set a service strategy to keep your lab running at full potential.

Section of your upkeep ought to be constructed in programs for replacement because regardless of how well you look after your test chambers, they’ll someday grow obsolete. The period varies from model to simulate. It is essential to keep tabs on how well they are doing, even if you’re not actively analyzing. It helps inform your replacement choices or help you identify areas of demand as your needs change. These are a few things to think about for determining when to purchase new environmental test chambers. Nonetheless, the particulars of the testing you need ought to factor into your choice. Regardless of what you decide on, use a trustworthy maker, and think about the pros when determining if buying or leasing a test chamber can be ideal for you.

 

Is Renting an Environmental Test Chamber a Wise Decision?

Envirentonmal test chamber producrse provide rentals as a choice to give firms flexibility. However, the situation has to be only right to create leasing a test room a cheaper option. If you lease a test chamber, you need to pay a monthly fee and assume accountability for upkeep. The expenses of hiring an environmental test chamber version for over three months, by way of instance, is approximately equivalent to the price of buying a brand new one. You would have been moneyed and never leasing in any way.

 

When does leasing Go off Well?  

It is a favorite alternative for start-ups or new businesses.  When they have attained their desired output so that they can analyze their possible expansion, create a quality map of the product, recheck clients’ testing requirements, and create a buying decision from that point. Another involves specialization jobs. What is more accurate for businesses with one-time analyzing requirements and rigorous timelines set up to lease test chambers.

This is also right for businesses that test after every five decades the efficiency and quality standard vary, as well as the upkeep costs to maintain the test room running will cancel any temporary gains. In case you’ve got specific testing requirements, a company deadline, and a restricted budget, then leasing a chamber is the very best alternative. Otherwise, look at buying a new test chamber.

 

Thinking about Having a New Test Chamber? Cost Breakdown and ROI

Since you start discussions on purchasing an environmental test chamber, be aware some tools will assist you in getting through the procedure, including a price breakdown to find the best test chamber for you with a complete buyer’s guide. In studying them, you get a better comprehension of test chambers and also find many about the advantages of purchasing an environmental test chamber versus taking a chamber in rent. The procedure starts with a solid ROI.

A well-maintained environmental test chamber will stay operational for a decade or more. That usually means the enormous upfront cost is distributed with time and is possibly offset by increased gains. Past the ROI, purchasing a test room provides you control over just testing times and frequencies of tests per day. Suppose you leased a version for four months. When the renting period ends, you may realize products often require additional testing. During the stage, you’d want to buy a test chamber with urgency. That is why it is essential to get a diligent purchasing procedure.

You have to rate your short period necessities in addition to those who may come down online to gain from the buy genuinely. And like any substantial capital expenditure, the maker thinks. Using a new one that can provide a personalized solution and supply a support program that can maintain your chambers operating for up to 11 years.

DGBell is one of the most renowned companies that design, manufacture, standard maintained, and custom-designed environmental test chambers that meet your promising prerequisites. Feel free to contact me before purchasing a new one.

 

When You Should Replace Your Environmental Test Chamber?

Consider the very first car you bought. You changed the oil frequently, replaced the brake pads required, and introduced it for yearly inspections. Sooner or later, the costs to keep operating exceeded the price of a replacement automobile, or the repairs climbed so hard and complicated that they were not guaranteed to do the job. Every time you chose the wheel was a bet.

The very same situations perform with environmental test chambers. As a guideline (these amounts vary based on usage, version, and maintenance), the following three years per test room will begin requiring replacement components to maintain functionality. Well-maintained, elderly test chambers also often outlive the tech that turns them off and on. That is where the replacement dialog starts.

 

Is It a Wise Decision?

If the environmental test chamber works precisely the same degree, but it includes a broken or outdated electronic control, it will not necessarily expect a replacement. It may be retrofitted with the most recent technology (DGBell) at a lower price than buying a new chamber. But controllers need specific programming and wiring.

For elderly chambers, the expense of work and time it requires to retrofit might not be well worth it for that which ultimately will end up being a short-term repair. After ten decades, they don’t operate efficiently or keep the same amount as the components degrade. Older refrigeration substances that induce the compressors are tough to acquire, making cleaning difficult. If the test chamber is not coming close to hitting its initial specs, it might not be an indication of anything but an era.

 

Conclusion

In the end, operation, instead of age, is occasionally the greatest factor when picking a replacement. By way of instance, your business might have bought stock versions. It worked out alright for steady-state states, but the moment you had to check at the extreme temperatures range finishes, the compressors had been over-stressed. However, well, you keep the environmental chamber, you want a higher-performing version to finish your essential testing.

Purchasing or Leasing

 

Read More

Contact us if you have any query